ISi North America AMV8 User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
16
1. Remove both doors from the furnace.
2. Remove and save the screws holding the junction box to
the left side of the furnace.
3. Models that have the junction box located in the blower
compartment will need to rotate the junction box 180
degrees. Models that have the junction box located in the
burner compartment will need to move the juction box
directly over.
4. Attach the junction box to the right side of the furnace,
using the screws removed in step 2.
5. Check the location wiring. Confirm that it will not be
damaged by heat from the burners or by the rotation of the
fan. Also confirm that wiring location will not interfere with
filter removal or other maintenance.
After the junction box is in the desired location, use washers to
connect field-supplied conduit to the junction box in accordance
with NEC and local codes. Connect hot, neutral, and ground
wires as shown in the furnace wiring diagram. The wires and
ground screw are located in the furnace junction box.
Low voltage wires may be connected to the terminal strip as
shown in Figure 12.
IMPORTANT NOTE: To avoid possible equipment malfunction,
route the low voltage wires to avoid interference with filter removal
or other maintenance.
Integrated Ignition Control
WARNING
T
O AVOID THE RISK OF INJURY, ELECTRICAL SHOCK OR DEATH, THE FURNACE
MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR,
IN THEIR ABSENCE, WITH THE LATEST EDITION OF THE
N
ATIONAL
E
LECTRIC
C
ODE.
To ensure proper unit grounding, the ground wire should run
from the furnace ground screw located inside the furnace junction
box all the way back to the electrical panel. NOTE: Do not use
gas piping as an electrical ground. To confirm proper unit
grounding, turn off the electrical power and perform the following
check.
1. Measure resistance between the neutral (white)
connection and one of the burners.
2. Resistance should measure 10 ohms or less.
This furnace is equipped with a blower door interlock switch
which interrupts unit voltage when the blower door is opened for
servicing. Do not defeat this switch.
24 VOLT T HERMOSTAT WIRING
NOTE: Wire routing must not interfere with circulator blower
operation, filter removal, or routine maintenance.
As a two-stage furnace, the furnace integrated control module
provides terminals for both “W1” and “W2”, and “YLO” and “Y”
thermostat connections. This allows the furnace to support the
following system applications: ‘Two-Stage Heating Only’, ‘Two-
Stage Heating with Single-Stage Cooling’, and ‘Two-Stage
Heating with Two-Stage Cooling’. Refer to the following figures
and table for proper connections to the integrated control module.
Low voltage connections can be made through either the right or
left side panel. Thermostat wiring entrance holes are located in
the blower compartment. The following figure shows connections
for a “heat only” system and “heat/cool system”.
This furnace is equipped with a 40 VA transformer to facilitate
use with most cooling equipment. Consult the wiring diagram,
located on the blower compartment door, for further details of
115 Volt and 24 Volt wiring.
SINGLE STAGE THERMOSTAT APPLICATION
W
G
Y
Single-Stage Heating with Single-Stage Cooling
R
B/C G R W1 W2O
YLO
Y
DEHUM
TWIN
Y C
NEU
HOT
Furnace Integrated
Control Module
Thermostat
Single-Stage Heating with
Single-Stage Cooling
()
Remote
Condensing Unit
(Single-Stage Cooling)
Dehumidistat
[Optional]
NOTE:
To apply a single-stage heating thermostat, the
thermostat selector jumper on the integrated Control
module must be set on single stage.
W1
G
Y
Two-Stage Heating with Single-Stage Cooling
R
W2
B/C G R W1 W2O
YLO
Y
DEHUM
TWIN
Y C
NEU
HOT
Furnace Integrated
Control Module
Thermostat
Two-Stage Heating
with
Single-Stage Cooling
()
Remote
Condensing Unit
(Single-Stage Cooling)
Dehumidistat
[Optional]
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 35 36

Comments to this Manuals

No comments